This guide provides the configuration steps for RS485-based fuel sensors (e.g., '''OMNICOM485''') with Transight Telematics devices using commands.
This guide provides the configuration steps for RS485-based fuel sensors (e.g., '''OMNICOM485''') with Transight Telematics devices using commands.
   
   
==Step 1: Select and Enable the Fuel Sensor Type==
==Step 1: Select and Enable the Fuel Sensor Type==


Defines the fuel sensor model and how many sensors are connected.
Defines the fuel sensor model and how many sensors are connected.
Line 93: Line 93:
</pre>
</pre>
   
   
== Step 2: Configure Fuel Sensor Communication Parameters ==
== Step 2: Configure Fuel Sensor Communication Parameters ==


Defines communication mode, baud rate, address, output interval, and format.
Defines communication mode, baud rate, address, output interval, and format.
Line 139: Line 139:
</pre>
</pre>
   
   
== 📌 Parameter Reference Table ==
== Parameter Reference Table ==


{| class="wikitable"  
{| class="wikitable"  
Line 186: Line 186:
</pre>
</pre>
   
   
== Step 3: Verify Fuel Data Transmission ==
== Step 3: Verify Fuel Data Transmission ==


After configuration, the device starts transmitting real-time fuel data via telemetry packets.
After configuration, the device starts transmitting real-time fuel data via telemetry packets.

Revision as of 11:46, 30 June 2025

Introduction to the Product

ITALON Fuel Level Sensors (FLS) measure fuel level in fuel tanks of the vehicles and stationary objects. ITALON FLS are connected to GPS devices which in turn transfer all the data along with the fuel information to a server part of the solution.

Parameter Value
Error in measurement ± 0.5%
Interface RS-485
Power supply voltage 7…40V
Insulation breakdown protection 2500V
Operating temperature -40…+85°C
Measurement range of digital interface 0…4095

Wiring Information

Wire Colour Function
Brown
Power
White GND
Orange RS485A
Blue RS485B

Configuration Guide

This guide provides the configuration steps for RS485-based fuel sensors (e.g., OMNICOM485) with Transight Telematics devices using commands.

Step 1: Select and Enable the Fuel Sensor Type

Defines the fuel sensor model and how many sensors are connected.

🔹 Command Format


SET CUFUELTYPE:<Sensor Model>,<Number of Sensors>

🔹 Example


SET CUFUELTYPE:OMNICOM485,1

🔹 Expected Response


IMEI: 862942074896044

Command: SET CUFUELTYPE:OMNICOM485,1
 
Response: OMNICOM485,

Error: 0

🔹 Verification Command


GET CUFUELTYPE

🔹 Expected Verification Response


IMEI: 862942074896044

Command: GET CUFUELTYPE
 
Response: OMNICOM485,1

Error: 0

Step 2: Configure Fuel Sensor Communication Parameters

Defines communication mode, baud rate, address, output interval, and format.

🔹 Command Format


SET CUFUELDATACFG:<Sensor Model>,<Index>,<Mode>,<Baud Rate>,<Network Address>,<Output Interval>,<Output Format>,<Range>

Example


SET CUFUELDATACFG:OMNICOM,1,MASTER_BINARY,19200,02,12,BINARY,1023

🔹 Expected Response


IMEI: 862942074896044

Command: SET CUFUELDATACFG:OMNICOM,1,MASTER_BINARY,19200,02,12,BINARY,1023
 
Response:

Error: 0

🔹 Verification Command


GET CUFUELDATACFG:OMNICOM,1

🔹 Expected Verification Response


IMEI: 862942074896044

Command: GET CUFUELDATACFG:OMNICOM,1
 
Response: Mode: 1, BaudRate: 19200, Address: 2, Interval: 12, Default Output: 1

Error: 0

Parameter Reference Table

Parameter Value Example Description
<Sensor Model> OMNICOM Sensor type (OMNICOM485, TECHNO485, ESCORT485, OFF)
<Index> 1 Sensor index (0–3)
<Mode> MASTER_BINARY Communication mode: SLAVE, MASTER_BINARY, MASTER_ASCII
<Baud Rate> 19200 Communication speed (in bps)
<Network Address> 02 RS485 device address (Hexadecimal 00–FF)
<Output Interval> 12 Interval in seconds between sensor readings
<Output Format> BINARY Data format (BINARY or ASCII)
<Range> 1023 Raw value range of the sensor output (e.g., 1023 or 4095)

⚠️ Mandatory Save Command

After completing configuration, execute this command to save settings:


SET TSMR:2

Step 3: Verify Fuel Data Transmission

After configuration, the device starts transmitting real-time fuel data via telemetry packets.

🔍 Validation Steps

  • Monitor server-side data packets.
  • Confirm:
    • Fuel data values are present.
    • Updates occur at the configured interval.
    • Values are within the expected range.

Note: If fuel data does not appear in packets, recheck wiring and configuration.