EUROSENSE DOMINATOR: Difference between revisions
No edit summary |
|||
| Line 179: | Line 179: | ||
<pre> | <pre> | ||
SET | SET CUMR:2 | ||
</pre> | </pre> | ||
Revision as of 05:19, 21 October 2025
Introduction to the Product
Eurosens sensors are designed to measure fuel level in tanks of vehicles and stationary units. The sensors are used in fleet management systems to monitor real fuel consumption, discharges, and refuelling. Sensors can measure POL (gasoline, kerosene, oil), which freely move inside measuring electrodes.
Product Specification

| Parameter | Value |
|---|---|
| Measurement range, mm | 20–1500 (with single electrode) / 20–10000 (with composite electrodes) |
| Power supply, V | 10–50 |
| Reverse polarity protection | Yes |
| Measurement error | ±1% |
| Data averaging period, sec | 1–300 |
| Max current consumption at 12 V, mA | ≤ 50 |
| Max current consumption at 24 V, mA | ≤ 25 |
| Ambient operating temperature, °C | -40 to +85 |
| Electromagnetic compatibility | UNECE Regulation №10 (05), TR CU 020 |
| Galvanic isolation of measuring electrodes from external circuits | Up to 1500 V |
| Ingress protection rating | IP67 |
| Cable length | 7m (other lengths available on request) |
| Tank calibration in sensor memory | Supported |
| Explosion proof certificate | 0ExiiaIIBT6 X |
| Built-in power battery | ER14505H, 3.6 V |
| Internal battery life, years | 5 |
| Measurement error | ±1% |
| Data averaging period, sec | 4, 8, 16, 32, 64, 128 |
| Data sending interval, sec | 2–1800 |
Wiring Information
| Wire Colour | Function |
|---|---|
| Red | Power |
| Brown | GND |
| Yellow | RS485 A |
| Green | RS485 B |
Configuration Guide
This guide outlines how to configure the RS485-based EUROSENS fuel sensor on Transight Telematics devices using configuration commands.
✅ Step 1: Select and Enable the Fuel Sensor Type
Defines the fuel sensor model and number of sensors connected.
• Command Format
SET CUFUELTYPE:<Sensor Model>,<Number of Sensors>
• Example
SET CUFUELTYPE:EUROSENS485,1
• Expected Response
IMEI: 862942074896044 Command: SET CUFUELTYPE:EUROSENS485,1 Response: EUROSENS485, Error : 0
• Verification Command
GET CUFUELTYPE
• Expected Verification Response
IMEI: 862942074896044 Command: GET CUFUELTYPE Response: EUROSENS485,1 Error : 0
✅ Step 2: Configure Fuel Sensor Communication Parameters
Defines sensor index and RS485 network address.
• Command Format
SET CUFUELDATACFG:<Sensor Type>,<Index>,<Network Address>
• Example
SET CUFUELDATACFG:EUROSENS,01,01
• Expected Response
IMEI: 862942074896044 Command: SET CUFUELDATACFG:EUROSENS,01,01 Response: Error : 0
• Verification Command
GET CUFUELDATACFG:EUROSENS,1
• Expected Verification Response
IMEI: 862942074896044 Command: GET CUFUELDATACFG:EUROSENS,01 Response: Mode: 0, BaudRate: 19200, Address: 1, Interval: 10, Default Output: 1 Error : 0
📋 Parameter Reference Table
| Parameter | Value Example | Description |
|---|---|---|
| Param1 | EUROSENS | Sensor type identifier |
| Param2 | Index = 1 | Sensor instance (1 to 3 supported) |
| Param3 | Network Address = 0x01 | RS485 address (0x00 to 0xE7 range) |
⚠️ Mandatory Save Command
After completing configuration, execute this to save and apply changes:
SET CUMR:2
✅ Step 3: Verify Fuel Data Transmission
Once configured, the device automatically starts transmitting real-time fuel data.
🔍 Validation Checklist
- Monitor telemetry packets on your server.
- Confirm:
- Fuel level data is present.
- Values update periodically.
- Readings are accurate and consistent.