== Product Specification ==
== Product Specification ==
 
[[File:Escort.png|right|250px]]
{| class="wikitable" style="width: 70%;"
{| class="wikitable" style="width: 70%;"
! style="background-color:#800020; white-space:nowrap; color:white;" | Parameter
! style="background-color:#800020; white-space:nowrap; color:white;" | Parameter
Line 54: Line 54:
This guide outlines how to configure the RS485-based ESCORT 485 fuel sensor on '''Transight Telematics''' devices using commands.
This guide outlines how to configure the RS485-based ESCORT 485 fuel sensor on '''Transight Telematics''' devices using commands.
   
   
== Step 1: Select and Enable the Fuel Sensor Type ==
== Step 1: Select and Enable the Fuel Sensor Type ==


Defines the sensor model and number of sensors.
Defines the sensor model and number of sensors.
Line 100: Line 100:
</pre>
</pre>
   
   
== Step 2: Configure Fuel Sensor Communication Parameters ==
== Step 2: Configure Fuel Sensor Communication Parameters ==


Set communication mode and output settings.
Set communication mode and output settings.
Line 146: Line 146:
</pre>
</pre>
   
   
== 📋 Parameter Reference Table ==
== Parameter Reference Table ==


{| class="wikitable"
{| class="wikitable"
Line 168: Line 168:
|}
|}
   
   
== Step 3: Set Fuel Sensor Output Interval ==
== Step 3: Set Fuel Sensor Output Interval ==


Configures periodic data transmission interval.
Configures periodic data transmission interval.
Line 204: Line 204:
</pre>
</pre>
   
   
== Step 4: Verify Fuel Data Transmission ==
==Step 4: Verify Fuel Data Transmission ==


Once configured, the device will transmit fuel data via telemetry.
Once configured, the device will transmit fuel data via telemetry.

Revision as of 12:00, 30 June 2025

Introduction to the Product

The sensor ESCORT TD-150 determines the fill level of light oils in reservoirs (storage tanks). It is used as a fuel sensor in the automotive engineering field, and also as a level sensor for any light oils in industrial applications. The sensor converts the calculated fuel level into a digital code, frequency, or analog signals. It is a complete, finished solution.

To ensure explosion protection, it is necessary to connect a resistor of the appropriate rating to the power supply circuit. The presence of a resistor depends on the scope of delivery.

Product Specification

Parameter Value
Power supply voltage 7 – 80 V
Current, no more 30 mA
Reduced measurement error in the effective range up to 1% UML22
Operating modes Digital, Frequency, Analog
Sensitivity (Receiver / Transmitter) -96 dBm / 4 dBm
Operating frequency range (BLE) 2.402 – 2.480 GHz
Ambient temperature -45 to +50 °C
Extreme ambient temperature -60 to +85 °C
Air pressure 84 – 106.7 kPa
Suitable for explosion hazardous areas Zones 0, 1, and 2
Weight (kg) 0.35 + 0.4 × L (L = sensor length in meters)

Wiring Information

Wire Color Function
Red Power
Black GND
Orange RS485 A
White RS485 B

Configuration Guide

This guide outlines how to configure the RS485-based ESCORT 485 fuel sensor on Transight Telematics devices using commands.

Step 1: Select and Enable the Fuel Sensor Type

Defines the sensor model and number of sensors.

• Command Format


SET CUFUELTYPE:<Sensor Model>,<Number of Sensors>

• Example


SET CUFUELTYPE:ESCORT485,1

• Expected Response


IMEI: 862942074896044

Command: SET CUFUELTYPE:ESCORT485,1
 
Response: ESCORT485, 

Error : 0

• Verification Command


GET CUFUELTYPE

• Expected Response


IMEI: 862942074896044

Command: GET CUFUELTYPE
 
Response: ESCORT485,1

Error : 0

Step 2: Configure Fuel Sensor Communication Parameters

Set communication mode and output settings.

• Command Format


SET CUFUELDATACFG:<Sensor>,<Index>,<Network Address>,<Mode>,<Filter Type>,<Filter>,<Interval>

• Example


SET CUFUELDATACFG:ESCORT,1,00,PASSIVE1023,SMART,SMART_0

• Expected Response


IMEI: 862942074896044

Command: SET CUFUELDATACFG:ESCORT,1,00,PASSIVE1023,SMART,SMART_0
 
Response:

Error : 0

• Verification Command


GET CUFUELDATACFG:ESCORT,1

• Expected Response


IMEI: 862942074896044

Command: GET CUFUELDATACFG:ESCORT,1
 
Response: Mode: 0, Address: 0, Filter Type: 0, Filter: 0 Interval: 0

Error : 0

Parameter Reference Table

Parameter Value Example Description
Param1 ESCORT Sensor type identifier
Param2 Index = 1 Defines sensor instance (1 to 3 supported)
Param2 Network Address = 0x01 RS485 address (0x00 to 0xE7)
Param3 Mode = PASSIVE1023 Modes: PASSIVE / FREQUENCY / PERIODIC with 1023 or 4095 resolution
Param4 Filtertype = SMART Type of filtering: SMART or MEDIAN
Param5 Filter = SMART_0 Filter preset: SMART_UPTO_200, SMART_200_1000, MEDIAN_0 to MEDIAN_9
Param6 Output interval = 10 Time between sensor readings (in seconds)

Step 3: Set Fuel Sensor Output Interval

Configures periodic data transmission interval.

• Command Format


SET CUFUELMODE:<SENSOR INDEX>,<Mode (1=Request, 0=Periodic)>,<Interval>

• Example


SET CUFUELMODE:1,1,15

• Expected Response


IMEI: 862942074896044

Command: SET CUFUELMODE:1,1,15
 
Response:

Error : 0

⚠️ Mandatory Save Command

After completing all configurations, save them with:


SET TSMR:2

Step 4: Verify Fuel Data Transmission

Once configured, the device will transmit fuel data via telemetry.

🔍 Validation Checklist

  • Monitor incoming telemetry on your server
  • Confirm:
    • Fuel level values are present
    • Values update periodically
    • Readings are consistent and accurate


Product Link