Jump to content

TECHNOTONE DUT-E 485 FUEL SENSOR

From Transight Wiki
Revision as of 04:52, 24 June 2025 by Editor (talk | contribs)

Introduction to the Product

DUT-E fuel level sensor is used for accurate fuel level and volume measurement in tanks of vehicles and stationary units. DUT-E helps determine current fuel volume and detect changes (such as refueling or draining) in the fuel tank.

It is widely used in GPS tracking and vehicle telematics systems, either as an additional fuel sensor or as a replacement for the factory-installed sensor. When integrated into a telematics system, DUT-E provides reliable and precise data on fuel levels, helping detect fuel misuse and theft, and offering a comprehensive view of fuel consumption.

Product Specification

Parameter Value
Operating principle Capacitive
Relative measuring error (to measuring length), % ±1%
Power supply voltage range 10 – 50 V
Consumption current at 12 V ≤ 50 mA *
Consumption current at 24 V ≤ 25 mA *
Availability time after power-up ≤ 10 seconds
Temperature range -40 to +85 °C
Ingress protection rating IP55/57
Electromagnetic compatibility
  • ESD Protection (Level II) – GOST 30378, GOST R 50607
  • EMI Protection (Level IV) – STB ISO 7637-2, GOST 28751

Wiring Information

Wire color Function
Orange Power
Brown GND
Red RS485 A
White RS485 B

Device Configuration

  1. Connect the DUT-E sensor to the device via RS-485 ports.
  2. Open the configurator tool GUI_v2/v3.
  3. Click on Connect Sensor.
  4. For **Automatic mode**, set the "Automatic Transmission mode" to hex format with a desired time interval.
  5. For **Request mode**, disable "Automatic Transmission mode".
  6. Click on Save to Sensor.
  7. Now use the QCOM Tool to verify that the fuel data is visible after proper configuration.

Command Reference

For Active Mode

SET CUENSDA:ON,CUSRLSRC:TECHNO485,CUSRLDATACFG:1-0-0-0-0-0-0-0-0

For Request Mode

SET CUENSDA:ON,CUSRLSRC:TECHNO485,CUSRLDATACFG:1-0-0-0-0-0-0-0-0
SET CUENFUELREQ:1,CUFUELNOS:1,CUFUELUR:10,CUFUELINT:5

// CUENFUELREQ:0 - Request mode disabled
// CUENFUELREQ:1 - Request mode enabled

SET CUFUELDATAREQ:1-0x31-0x01-0x06-0x6c

// First bit = Number of fuel sensors
// CRC for 1 sensor = 0x31-0x01-0x06-0x6c

For Connecting Parallel Fuel Sensors (2 Sensors)

SET CUENSDA:ON,CUSRLSRC:TECHNO485,CUSRLDATACFG:1-0-0-0-0-0-0-0

SET CUENFUELREQ:1,CUFUELNOS:2,CUFUELUR:10,CUFUELINT:5

// CUENFUELREQ:0 - Request mode disabled
// CUENFUELREQ:1 - Request mode enabled

SET CUFUELDATATEQ:2-0x31-0x02-0x06-0x39

// First bit = Number of fuel sensors
// CRC for 2 sensors = 0x31-0x02-0x06-0x39

Product Link

[Technoton FLS]