ITALON FUEL SENSOR
Introduction to the Product
ITALON Fuel Level Sensors (FLS) measure fuel level in fuel tanks of the vehicles and stationary objects. ITALON FLS are connected to GPS devices which in turn transfer all the data along with the fuel information to a server part of the solution.

| Parameter | Value |
|---|---|
| Error in measurement | ± 0.5% |
| Interface | RS-485 |
| Power supply voltage | 7…40V |
| Insulation breakdown protection | 2500V |
| Operating temperature | -40…+85°C |
| Measurement range of digital interface | 0…4095 |
Wiring Information
| Wire Colour | Function |
|---|---|
| Brown | Power |
| White | GND |
| Orange | RS485A |
| Blue | RS485B |
Configuration Guide
This guide provides the configuration steps for RS485-based fuel sensors (e.g., OMNICOM485) with Transight Telematics devices using commands.
Step 1: Select and Enable the Fuel Sensor Type
Defines the fuel sensor model and how many sensors are connected.
🔹 Command Format
SET CUFUELTYPE:<Sensor Model>,<Number of Sensors>
🔹 Example
SET CUFUELTYPE:OMNICOM485,1
🔹 Expected Response
IMEI: 862942074896044 Command: SET CUFUELTYPE:OMNICOM485,1 Response: OMNICOM485, Error: 0
🔹 Verification Command
GET CUFUELTYPE
🔹 Expected Verification Response
IMEI: 862942074896044 Command: GET CUFUELTYPE Response: OMNICOM485,1 Error: 0
Step 2: Configure Fuel Sensor Communication Parameters
Defines communication mode, baud rate, address, output interval, and format.
🔹 Command Format
SET CUFUELDATACFG:<Sensor Model>,<Index>,<Mode>,<Baud Rate>,<Network Address>,<Output Interval>,<Output Format>,<Range>
Example
SET CUFUELDATACFG:OMNICOM,1,MASTER_BINARY,19200,02,12,BINARY,1023
🔹 Expected Response
IMEI: 862942074896044 Command: SET CUFUELDATACFG:OMNICOM,1,MASTER_BINARY,19200,02,12,BINARY,1023 Response: Error: 0
🔹 Verification Command
GET CUFUELDATACFG:OMNICOM,1
🔹 Expected Verification Response
IMEI: 862942074896044 Command: GET CUFUELDATACFG:OMNICOM,1 Response: Mode: 1, BaudRate: 19200, Address: 2, Interval: 12, Default Output: 1 Error: 0
Parameter Reference Table
| Parameter | Value Example | Description |
|---|---|---|
| <Sensor Model> | OMNICOM | Sensor type (OMNICOM485, TECHNO485, ESCORT485, OFF) |
| <Index> | 1 | Sensor index (0–3) |
| <Mode> | MASTER_BINARY | Communication mode: SLAVE, MASTER_BINARY, MASTER_ASCII |
| <Baud Rate> | 19200 | Communication speed (in bps) |
| <Network Address> | 02 | RS485 device address (Hexadecimal 00–FF) |
| <Output Interval> | 12 | Interval in seconds between sensor readings |
| <Output Format> | BINARY | Data format (BINARY or ASCII) |
| <Range> | 1023 | Raw value range of the sensor output (e.g., 1023 or 4095) |
⚠️ Mandatory Save Command
After completing configuration, execute this command to save settings:
SET CUMR:2
Step 3: Verify Fuel Data Transmission
After configuration, the device starts transmitting real-time fuel data via telemetry packets.
🔍 Validation Steps
- Monitor server-side data packets.
- Confirm:
- Fuel data values are present.
- Updates occur at the configured interval.
- Values are within the expected range.
Note: If fuel data does not appear in packets, recheck wiring and configuration.