Configuration Commands Example and Response Description Commnad Type (SET/GET)
URL SET CUURL:TCP:<IP>:<PORT>
SET CUURL:url (HTTP)

Example:
SET CUURL:http://livedata.transight.net:6000/data
SET CUURL:TCP:15.235.9.66:50334
GET CUURL
Response:
URL:http://livedata.customert.net:6000/data
URL:TCP:15.235.9.66:50334
To SET and GET server URL for customer and transight IPs in HTTP and TCP protocol.
Data packets will send from device to the pointed IP address.
SET GET
UR(in seconds). SET CUUR:<duration>
GET CUUR
Example:
SET CUUR:30
GET CUUR
Response:
UR: 30
Update rate in motion, duration is in seconds
Packets will be generating in this frequency.
SET, GET
URT(halt,in minute). SET CUURT:<duration in mins>
GET CUURT
Example:
SET CUURT:30
GET CUURT
Response:
CUURT: 30
Update rate in halt, duration is in minutes SET, GET
URS(sleep, in minute). SET CUURS:<duration>
GET CUURS
Example:
SET CUURS:30
GET CUURS
Response:
CUURS: 30
Update rate in sleep, duration is in minutes SET, GET
M1 SET CUM1:<+91xxxxxxxxxx>
GET CUM1
Response:
M1: +919656691846
This enables the customer to configure the device and setup alert recipients. SET, GET
M2 SET CUM2:<+91xxxxxxxxxx>
GET CUM2
Response:
M2: +919656691846
Secondary mobile number for alerts SET, GET
APN SET CUAPN:<APN>
M2MISAFEcom(For VI)
airtelgprs.com(For Airtel)
GET CUAPN
Response:
APN:M2MISAFE
Access Point Name (APN) for internet connectivity SET, GET
FRNO SET CUFRNO:<number>
GET CUFRNO
Example:
SET CUFRNO:12
GET CUFRNO
Response:
FRNO:12
This command is used to get or set the current frame number. The frame numbers are generated in sequential order. SET GET
FSMODE SET CUFSMODE:<0/1>
GET CUFSMODE
Example:
SET CUFSMODE:1
GET CUFSMODE
Response:
FSMODE:1
This command would set the file system mode:
0-FIFO
1-LIFO
SET GET
IOCFG SET CUIOCFG:<IO Number>-<IO Mode>-<IO Function*>-<IO Number>-<IO Mode>-<IO Function*>-<IO Number><IO Mode>-<IO Function*>
Example:
SET CUIOCFG:IO1-DI-GEN*IO2-DO-GEN*IO3-AN-GEN*
GET CUIOCFG
Response
CUIOCFG:
IO1-DI-GEN*IO2-DO-GEN*IO3-AN-GEN
This command is used to configure the pin as Digital Input, or Digital Output, or Analog.
AN - Analog
DO - Digital Output
DI - Digital Input
SET GET
ENIP SET CUENIP:<IP>.<state>,<IP>.<state>
Example:
SET CUENIP:0.1,1.0
GET CUENIP
Response:
ENIP:0.1,1.0
IP:Transight-0, Customer-1

State:
1- Enabled
0- Disabled
ENIP:0.1,1.1

SET GET
DO SET CUDO:1.n,2.n (n=0:off,1:on)

GET CUDO
Response:
DO 1:OFF/ON-DO 2:OFF/ON

Pin Number: 1 or 2
Pin State: 0-off, 1-On
Each pin configuration separated by"",""
SET GET
VID SET CUVID:TRANSI
GET CUVID
Response:
VID: TRANSI
Set/Get vendor ID SET GET
DI GET CUDI
Response:
DI:000
Get digital input status GET
AI GET CUAI
Response:
AI:0-0-0
Get analog input voltage values GET
GF Polygon:
SET CUGF:<Status><geofence ID>-<alert type>-<shape>#<latitude-longitude>#....&

Circle:
SET CUGF:<Status><geofence ID>-<alert type>-<shape>#<latitude-longitude (center point of circle)>#<radius in meter>
Example for Polygon:
SET CUGF:1-1777-3-1#10.0535097-76.334262#10.0504267-76.3328855#10.0474386-76.3439598#10.0503084-76.3437023#10.0535097-76.334262&
Example for Circle:
SET CUGF:1-1313-30#10.055625576.3544891#1000GET CUGF
Response:
NO of geofences: 1

Status
0 - Disable
1 - Enable

Shape
0 - circle
1 - polygon
Alert type
1-entry
2-exit
3-entry & exit

SET GET
FUELTYPE & FUELCFG for TECHNO

SET CUFUELTYPE:TECHNO485,1 SET CUFUELDATACFG:TECHNO,1,REQUEST,PERCENT,19200,01,20,01,PRE,POST,160,0,100,410

================OR==================================================

SET CUFUELDATACFG:TECHNO,1,PUSH_HEX,PERCENT,19200,01,20,01,PRE,POST,160,0,100,410

====================================================================

for ESCORT, SET CUFUELTYPE:ESCORT485,1 SET CUFUELDATACFG:ESCORT,01,04,PERIODIC1023,SMART,SMART_0,15

=================OR================================================

SET CUFUELDATACFG:ESCORT,01,04,PASSIVE1023,SMART,SMART_0,15 SET CUFUELMODE:1,1,15

====================================================================

FOR ITALON SET CUFUELTYPE:OMNICOM485,1 MASTER CONFIGURATIONS SET CUFUELDATACFG:OMNICOM,1,MASTER_BINARY,19200,02,12,BINARY,1023

==============OR====================================================

for slave mode: SET CUFUELDATACFG:OMNICOM,1,SLAVE,19200,02,12,BINARY,1023

====================================================================

FOR STRELLA SET CUFUELTYPE:STRELLA232,1 SET CUFUELDATACFG:STRELLA,1,REQUEST,01,20 or SET CUFUELDATACFG:STRELLA,1,PUSH_HEX,01,20

=====================================================================

FOR EUROSENS SET CUFUELTYPE:EUROSENS485,1 SET CUFUELDATACFG:EUROSENS,01,01

SET GET
DEVI GET CUDEVI
Response: device info packet
Get complete hardware and firmware details from the device GET
DEVCFG GET CUDEVCFG
Response: configuraton info packet
Get entire configuration from device GET
IMOB SET CUIMOB:<ON/OFF>
GET CUIMOB
Example:
SET CUIMOB:OFF
GETCUIMOB
Response:
IMOB:OFF
Enable/Disable Immobilizer feature SET GET
SL SET CUSL:<Limit>
GET CUSL
Example:
SET CUSL:70
GET CUSL
Response:
SPEEDLIMIT: 70
Configure speed limit for alerts SET GET
ACCELENABLE SET CUACCELENABLE:<0/1>
Example:
SET CUACCELENABLE:1
GET CUACCELENABLE
Response:
ACCELERO_ENABLE_STATUS: 1
1 - Enable
0 - Disable
SET GET
ORIENTATION SET CUORIENTATION:<orientation number>
Example:

SET CUORIENTATION:1
GET CUORIENTATION
Response:
1

Device mounting orientation:
Orientation Number Explanation:

1 - Horizontal, power cable towards the driver, Antenna sky facing
2 - Vertical , power cable downward, Antenna facing driver
3 - Horizontal, power cable to the right, Antenna sky facing
4 - Vertical , power cable to the right, Antenna facing driver

SET GET
TA SET CUTA:40
GET CUTA
Response:
TILT ANGLE THRESHOLD: 40
Tilt alert threshold in degrees SET GET
VN SET CUVN:<Vehicle No>
Example:
SET CUVN:<XXXXXXX>
GET CUVN
Response:
VEHICLE_REG_NUMBER: XXXXXXX
Set/Get vehicle number SET GET
CH SET CUCH Clearing history logs from device memory. SET
MR SET CUMR:<Number> Microcontroller Restart:

1. Network Modem Immediate Restart
2. Network Modem Normal Restart, NVM Write true
3. Supervisory Controller Restarts Network Module
4. Supervisory Controller Immediate Restart
5. Supervisory Conteoller Normal Restart, NVM Write true

SET
FWINFO GET CUFWINFO
Response:
FWINFO: TSD4G_0_3.0.2
FWINFO: TSDRB_0_3.0.1
FWINFO: TSD4R_0_1.0.3
Get firmware version info for:
- Network Modem
- Bootloader
- Supervisory Controller
GET
IMEI GET CUIMEI
Response:
IMEI: 869137069984441
Get device IMEI number GET
SPI GET CUSPI
Response:
REMAINING PACKETS=1566
Shows number of unsent packets stored in memory GET
LOC GET CULOC
Response:
LOC:Fix:0,Lat:0.000000,Lon:0.0000000,...
Get latest GPS location from device GET
SUPT GET CUSUPT
Response:
DEVICE_UPTIME: X-days X-hrs X-mins X-sec
Command to get the time from which the device was switched on.
Response format:
DEVICE_UPTIME:<days>-<hours>-<minutes>-<seconds>
GET
ODOMODE SET CUODOMODE:<1/2>
GET CUODOMODE
Response:
CUODOMODE:1
Set odometer calculation mode:
0 - Differential
1 - Accumulated
SET GET
ODO SET ODO:<Number>
Example:
SET CUODO:111
GET CUODO
Response:
CUODO:111 METERS
Get/Set current odometer readings SET GET
NWI (Network Info) GET CUNWI
Response:
CUNWI:VI-404-19-1-1-20-0-0
Command to get the network information

Response Format: CUNWI:<Operator Name>-<MCC>-<MNC>-<GSM nw reg stat>-<GPRS nw reg stat>-<signal strength>-<GSM nw reg loss tmr>-<GPRS nw reg loss timer> GSM network registered status :

1 – Registration OK
2 - Searching
3 - Deny
5 – Registration OK Roaming
0 – Not registered

GPRS network registered status

1 – Registration OK
2 - Searching
3 - Deny
5 – Registration OK Roaming
0 – Not registered

Signal Strength: 1 -31 in ASW
GSM network registered loss timer : Time is seconds elapsed after GSM network registration loss
GPRS network registered loss timer : Time is seconds elapsed after GPRS network registration loss

GET
COMSTAT GET CUCOMSTAT
Response:
COMSTAT:4-0
Get communication success/failure counts GET
ENOW SET CUENOW:ON/OFF
GET CUENOW
Response:
ENOW:OFF
Enable/Disable 1-wire sensor port SET GET
OWCFG SET CUOWCFG:<Sensor name>
GET CUOWCFG
Example:
SET CUOWCFG:DS18B20
GET CUOWCFG
Response:
DS18B20
Configure the 1-wire sensor models
1-BS18B20
2-AM2305
SET GET
OWNOS SET CUOWNOS:<No's>
Example:
SET CUOWNOS:2
GET CUOWNOS
Response:
TEMPERATURE SENSOR NOS: 2
Number of 1-wire sensors connected SET GET