Introduction to the Product

The sensor ESCORT TD-150 determines the fill level of light oils in reservoirs (storage tanks). It is used as a fuel sensor in the automotive engineering field, and also as a level sensor for any light oils in industrial applications. The sensor converts the calculated fuel level into a digital code, frequency, or analog signals. It is a complete, finished solution.

To ensure explosion protection, it is necessary to connect a resistor of the appropriate rating to the power supply circuit. The presence of a resistor depends on the scope of delivery.

Product Specification

Parameter Value
Power supply voltage 7 – 80 V
Current, no more 30 mA
Reduced measurement error in the effective range up to 1% UML22
Operating modes Digital, Frequency, Analog
Sensitivity (Receiver / Transmitter) -96 dBm / 4 dBm
Operating frequency range (BLE) 2.402 – 2.480 GHz
Ambient temperature -45 to +50 °C
Extreme ambient temperature -60 to +85 °C
Air pressure 84 – 106.7 kPa
Suitable for explosion hazardous areas Zones 0, 1, and 2
Weight (kg) 0.35 + 0.4 × L (L = sensor length in meters)

Wiring Information

Wire Color Function
Red Power
Black GND
Orange RS485A
White RS485B

Device Configuration

  1. Connect the sensor to the RS-485 port on the device.
  2. Open the Escort Configurator tool.
  3. Connect the COM Port and select FLS. The value present in the sensor will load.
  4. If the sensor is in **periodic mode**, data will be sent every 2 seconds (fixed interval).
  5. If the sensor is in **passive mode**, data will be sent only on request.
  6. Connect using the QCOM tool to verify whether the fuel data is visible after configuring parameters for the connected fuel sensor.

Command Reference

For Active Mode

SET CUENSDA:ON,CUSRLSRC:SRLGEN,CUSRLDATACFG:1-0-0-0-0-0-0-0-0

For Request Mode

SET CUENSDA:ON
SET CUSRLSRC:<sensor model>
    ESCORT485  --> For Escort Fuel sensor
    SRLGEN     --> For other fuel sensors
SET CUSRLDATACFG:1-0-0-0-0-0-0-0-0
SET CUFUELUR:20             // Set request interval in seconds
SET CUENFUELREQ:1           // Enable request mode (1: Enable, 0: Disable)
SET CUFUELNOS:<no.of sensors>
SET CUFUELDATAREQ:1-0x31-0x01-0x06-0x6c    // Get fuel data
SET CUESCOSTAT:0x31-0x01-0xf0-0xc5         // Get sensor status from escort fuel sensor. 
SET CUESCOMED:0x31-0x01-0xF2-0xA5-0x1B-0xC7-0x00-0x45-0x83    // Get median 5
GET CUSRLDATA              // Get SMS Response for above commands