Jump to content

ITALON FUEL SENSOR

From Transight Wiki
Revision as of 12:14, 24 June 2025 by Editor (talk | contribs)

Introduction to the Product

ITALON Fuel Level Sensors (FLS) measure fuel level in fuel tanks of the vehicles and stationary objects. ITALON FLS are connected to GPS devices which in turn transfer all the data along with the fuel information to a server part of the solution.

Parameter Value
Error in measurement ± 0.5%
Interface RS-485
Power supply voltage 7…40V
Insulation breakdown protection 2500V
Operating temperature -40…+85°C
Measurement range of digital interface 0…4095

Wiring Information

Wire Colour Function
Brown Power
White GND
Orange RS485A
Blue RS485B

Device Configuration

  1. Connect the sensor to the device using the RS-485 ports.
  2. Open the configurator tool DUTconf.exe to verify the sensor’s operational status.
  3. Use the QCOM tool to confirm that the fuel data is being displayed.
  4. Ensure the necessary parameters are correctly configured on the device for the connected fuel sensor.

For Active Mode, use the following command:

SET CUENSDA:ON,CUSRLSRC:SRLGEN,CUSRLDATACFG:1-0-0-0-0-0-0-0-0

Product Link

[ITALON FLS